| Scales | Refractive Index | 1.32 ~ 1.42 | 1.32 ~ 1.54 | 1.32 ~ 1.54 | 
                  
                   | Sugar 
				   (¡ÆBrix) | 0 ~ 50 | 0 ~ 100 | 0 ~ 100 | 
				  
                  | User-defined | 100 | 100 | 100 | 
				  
                   | Resolution | Refractive Index | 0.0001 | 0.0001 | 0.00001 | 
				  
                   | Sugar 
				   (¡ÆBrix) | 0.1 | 0.1 | 0.01 | 
				  
                   | Accuracy | Refractive Index | ¡¾0.0001 | ¡¾0.0001 | ¡¾0.00005 | 
				  
                   | Sugar 
				   (¡ÆBrix) | ¡¾0.1 | ¡¾0.1 | ¡¾0.04 | 
				  
                  | Precision (Reproducibility) | Refractive Index | ¡¾ 0.00005 | ¡¾ 0.00005 | ¡¾ 0.00001 | 
				  
                   | Sugar 
				   (¡ÆBrix) | ¡¾ 0.05 | ¡¾ 0.05 | ¡¾ 0.01 | 
				  
                  | User Scale 
				  Library | 20+ pre-programmed scales 
				  including HFCS (3), Sugar (4), Honey, NaCl, Wine Must (5), Urine SG (3), Glycol (2), Urea, FSII and more; plus customer 
				  programmable user scales via PC.
 | 
				  
                  | Reading Time | Minimum 4 seconds (optional time 
				  delay) | 
				  
                  | Temperature 
				  Control | None - Automatic Temperature 
				  Compensation (ATC) | 
				  
                  | Temperature 
				  Compensation | ICUMSA, AG, User, none | 
				  
                  | Sample 
				  Temperature Range | 0 ~ 100 ¡ÆC | 
				  
                  | Measuring 
				  Temperature Range | 5 ~ 40 ¡ÆC | 
				  
                  | Temperature 
				  Sensor Accuracy | ¡¾ 0.03 ¡ÆC | 
				  
                  | Sample 
				  Temperature Stability | ¡¾ 0.05 ¡ÆC | 
				  
                  | Temperature 
				  Compensation | Sucrose (¡ÆBrix) | 5 ~ 80 ¡ÆC | 
				  
                  | AG Fluids | 5 ~ 40 ¡ÆC | 
				  
                  | User-defined | Simple coefficient (units/ ¡ÆC) or 
				  polynomial function | 
				  
                  | Temperature 
				  Stability Checks | Delay in seconds or none | 
				  
                  | Sample 
				  Illumination | Light Emitting Diode 589nm 
				  (100,000+ hours) | 
				  
                  | Prism / Dish | Artificial Sapphire / Stainless 
				  Steel 316 / PEEK (spill barrier) | 
				  
                  | Prism Seal | Silicon/Resin | 
				  
                  | Interfaces | 1 x USB (A), 1 x USB (B), RS232 
				  via USB adaptor (optional accessory) | 
                 
                  | Power | Instrument: 24 V DC, ¡¾5%, <1A / 
				  External PSU: 100-240V, 50-60Hz (supplied) | 
              
                
                  | Humidity Range | <90% RH 
				  (non-condensing) |